TASARIMDAN İMALATA

Aluminium Alloys

Aluminium Alloys
← Back to Technical Information
Aluminium Alloys

Aluminium conditions O, H111, T6, T651 and T652 are not interchangeable. Figures below are Alimex PLANAL product examples; check thickness, direction and delivery condition in the data sheet.

5083: plates and fixtures. 6082: machined structural parts and fixtures. 7075: high-strength parts; assess welding and corrosion requirements separately.

Material / gradeDensity g/cm³Rm ≥ MPaRp0.2 ≥ MPaHB ≥Thermal conductivity W/(m·K)
PLANAL 5083 O/H1112.6627011573110–140
PLANAL 6082 T6512.729524089170–220
PLANAL 7075 T651/T6522.8495420147130–160

Values apply to the named commercial grade and test conditions, not to every material in the family. — means no verified value is provided here. Use the manufacturer's data sheet and material certificate.

Do not choose mould alloys by hardness alone. Consider conductivity, wear, corrosion, polishability, repair and heat transfer to cooling channels.