TASARIMDAN İMALATA
Aluminium Alloys


Aluminium conditions O, H111, T6, T651 and T652 are not interchangeable. Figures below are Alimex PLANAL product examples; check thickness, direction and delivery condition in the data sheet.
5083: plates and fixtures. 6082: machined structural parts and fixtures. 7075: high-strength parts; assess welding and corrosion requirements separately.
| Material / grade | Density g/cm³ | Rm ≥ MPa | Rp0.2 ≥ MPa | HB ≥ | Thermal conductivity W/(m·K) |
|---|---|---|---|---|---|
| PLANAL 5083 O/H111 | 2.66 | 270 | 115 | 73 | 110–140 |
| PLANAL 6082 T651 | 2.7 | 295 | 240 | 89 | 170–220 |
| PLANAL 7075 T651/T652 | 2.8 | 495 | 420 | 147 | 130–160 |
Values apply to the named commercial grade and test conditions, not to every material in the family. — means no verified value is provided here. Use the manufacturer's data sheet and material certificate.
Do not choose mould alloys by hardness alone. Consider conductivity, wear, corrosion, polishability, repair and heat transfer to cooling channels.