TASARIMDAN İMALATA

Injection Pressure and Clamping Force

Injection Pressure and Clamping Force
← Back to Technical Information
Injection Pressure and Clamping Force

A: total projected area of all cavities and cold runners on the parting plane (cm²). P: cavity pressure (bar). F: force (kN). Hydraulic pressure, plastic pressure ahead of the screw and cavity pressure are different.

F (kN) = A (cm²) × P (bar) / 100
1 tf = 9.80665 kN

Example: A = 200 cm², P = 400 bar → F = 800 kN ≈ 81.6 tonnes-force. This is a calculation example only; machine selection also requires an appropriate allowance, mould dimensions, tie-bar spacing and shot capacity.

A (cm²)P (bar)F (kN)F (tf)
5040020020.39
10040040040.79
20040080081.58
4004001600163.15

Filling → packing → cooling → opening → ejection. Filling is speed controlled; packing compensates shrinkage. Monitor transfer position, cushion and part weight together.

Technical sources