Plastic Moulding Shrinkage


s: shrinkage defined relative to the mould dimension; Lp: target part dimension; Lm: mould dimension. One fixed percentage per polymer family is unreliable. Grade, fibre reinforcement, flow direction, packing, mould temperature and measurement timing affect results.
| Material / grade | s (%) | ISO 294-4 |
|---|---|---|
| ABS — Terluran GP-35 | 0.4–0.7 | linear |
| PA6 — Ultramid B3S | 0.90 / 0.90 | parallel / transverse |
| PC — Makrolon 2405 | 0.65 | parallel to flow; 60×60×2 mm; 500 bar |
Values apply to the named commercial grade and test conditions, not to every material in the family. — means no verified value is provided here. Use the manufacturer's data sheet and material certificate.
Lm = Lp / (1 − s)
Assumed example: Lp = 100 mm, s = 1.5% → Lm = 101.523 mm. This is not a recommended material value. Obtain flow and transverse shrinkage from the grade data sheet and verify through mould trials.
| s (%) | Lp (mm) | Lm (mm) |
|---|---|---|
| 0.4 | 100 | 100.402 |
| 0.5 | 100 | 100.503 |
| 0.65 | 100 | 100.654 |
| 0.7 | 100 | 100.705 |
| 0.9 | 100 | 100.908 |
| 1 | 100 | 101.010 |
| 1.5 | 100 | 101.523 |
| 2 | 100 | 102.041 |
Dry and conditioned PA values differ. Moisture affects stiffness and dimensions; consider service humidity.